SPECIFICATION
MAINSTATION
PowerInput: availablein110V/220V
StationDimensions: 188(w)x126(h)x250(d)mm
Weight: 5.6Kg
SOLDERINGIRON
PowerConsumption: 70W
TemperatureRange: 250°C480°C
HeatingElement: CeramicHeater
OutputVoltage: 24V
HOTAIRGUN
PowerConsumption: 500W
TemperatureRange: 100°C480°C
HeatingElement MetalHeatingCore
Pump/MotorType: DiaphragmPump
AirCapacity: 23l/min(max)
DESOLDERINGGUN
TemperatureRange: 380°C480°C
HeatingElement: CeramicHeater
OutputVoltage: 36V
SuctionFlow: 15l/min(max)
VacuumGenerator: VacuumPump
VacuumPressure: 600mmHg
23
BASIC TROUBLESHOOTING GUIDE
PROBLEM6:THEUNITISVERYNOISY
SOLUTION:
Make sure the screw at the center of the base of the main unit has
beenremoved.Thisholdsthepumpinplaceduringtransportationand
needstoberemovedbeforeusingtheequipment.
PROBLEM7:AIRPRESSURELEVELISSIGNIFICANTLYLOWNO
MATTERHOWHIGHTHEAIRFLOWLEVELISCALIBRATED
Case 1: Check the mains voltage (AC power source). If the voltage
level falls significantly low, about 1520% lower than the standard,
therewillalsobeanoticeabledropintheairpressurelevel.
SOLUTION:
Pleaserefertoyourlocalpowerserviceprovider.
Case 2: The microcontroller might have detected the operating
frequency incorrectly. The user will notice thatairflow level is weaker
withreferencetotheairflowgaugecomparedwiththedisplayedvalue.
SOLUTION:
TrytopresstheRESETbuttononthepaneltoletthedevi ceredetect
theproperoperatingfrequency.Notethatresettingthedevicewillalso
resetallpreviouslydefinedconfigurationstosystemdefaultparameters.
Case3: TheSuctionVacuumcapisconnectedtotheSmokeAbsorber
TerminalorVacuumcapinsteadoftheFilterVacuumcap.
SOLUTION:
Change the cap to the Filter Vacuum cap or the cap with the wider
mouthpiece. This allows more air to pass through the system. Make
sureaswellthatthevacuumtubeofthesolderingironordesoldering
gunisnotconnected.